Mass Flow Meters

Digital Pressure Controller for Gasses with Integrated Flow Sensor
Technische specificaties red-y smart pressure controller
MEASURING RANGES FLOW | |
Air/Full scale freely selectable | Body size ¼” from 0 … 25 mln/min to 0 … 60 ln/min Body size ½” from 0 … 60 ln/min to 0 … 450 ln/min |
MEASURING RANGES PRESSURE | |
Full scale gauge pressure | 0.5 barg, 1 barg, 2 barg, 5 barg, 10 barg |
Full scale absolute pressure | 1.2 bara, 2 bara, 5 bara, 10 bara |
INSTRUMENT VERSIONS FLOW | |
“Standard” The economic solution | Accuracy: ± 1.0% of full scale* Turndown ratio: 1 : 50 |
“Hi-Performance” With highest accuracy and turndown ratio(available for GSB/GSP< 150 ln/min (air) | Accuracy: ± 0.3% of full scale + ± 0.5% of reading* Turndown ratio: 1 : 100*An additional error of ±0.25% may apply for analogue signals |
INSTRUMENT VERSIONS PRESSURE | |
Pressure control | Accuracy: ± 0.5 % of full scale |
Back pressure control | Accuracy: ± 0.5 % of full scale |
PERFORMANCE DATA | |
Media (real gas calibration) | Air*, O2*, N2, He, Ar, CO2, H2, CH4, C3H8 (other gases and gas mixtures on request) *O2 & N2 are calibrated with air |
Response time | 150 ms |
Repeatability | ± 0.2% of full scale |
Longterm stability | < 1% of measured value / year |
Power supply | 24 Vdc (18 – 30 Vdc), 15 Vdc on request |
Current consumption | max. 250 mA |
Temperature (environment/gas) | 0 – 50°C |
Body Materials | Anodized aluminium, optional stainless steel electropolished |
Seals | FKM, NBR, optional EPDM |
Pressure sensitivity | <0.2% / bar of reading (typical N2) |
Temperature sensitivity | 0.025% FS measuring range type / °C |
Warm-up time | <1 sec. for full accuracy |
INTEGRATION & INSTALLATION | |
Output signals analog | 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, 2-10 V (for actual value flow only) |
Output signals digital | RS-485; Modbus RTU (Slave) LabView-VIs availableOption: Profibus DP-V0, DP-V1(for pressure & flow) |
Process connection | G¼” (BSPP* female) up to 60 ln/min, G½” (BSPP* female) up to 450 ln/min*British Standard Pipe Parallel |
Inlet section | None required |
Electrical connection | Sub D plug, 9 pole |
Mounting orientation | Any orientation (horizontal only above 5 bar) |
SAFETY | |
Test pressure | 16 bara |
Leak rate | < 1 x 10-6 mbar l/s He |
Environmental protection | IP50 (conforms to NEMA 1) |
EMC | EN 61326-1 |
- software get red-y product information
- red-y smart series operating instructions sn>110000
- red-y smart series operating instructions digital communication
- red-y smart series display option
- red-y smart series cable accessories
- red-y smart pressure controller product information
- labVIEW VIs (labview 2010 and higher).zip
- labVIEW VIs (abview 86 and higher).zip
- labVIEW VIs (labview 6 and higher).zip
- software get red-y v56.zip
Any specific questions about this product?
Prefer a more personal approach? Call PhoneNumber or sent a mail to info@marktechnical.nl