Technical Specifications red-y smart series

MEASURING RANGES
Air/Full scale freely selectableBody size ¼” from 0 … 25 mln/min to 0 … 60 ln/min (from 0 … 27 SCCM to 0 … 64 SLPM)
Body size ½” from 0 … 60 ln/min to 0 … 450 ln/min (from 0 … 65 SLPM to 0 … 480 SLPM)
INSTRUMENT VERSIONS
“Standard”
The economic solution
Accuracy: ± 1.0% of full scale*
Turndown ratio: 1 : 50
“Hi-Performance”With highest accuracy and turndown ratio(available for GSM < 200 ln/min (200 SLPM) /GSC < 150 ln/min (150 SLPM) (air))Accuracy: ± 0.3% of full scale + ± 0.5% of reading*
Turndown ratio: 1 : 100*An additional error of ±0.25% may apply for analogue signals
PERFORMANCE DATA
Media (real gas calibration)Air*, O2*, N2, He, Ar, CO2, H2, CH4, C3H8 (other gases and gas mixtures on request)
*O2 & N2 are calibrated with air
Response timeMeter: 50 ms; Controller: 150 ms
Repeatability± 0.2% of full scale
Longterm stability< 1% of measured value / year
Power supply24 Vdc (18 – 30 Vdc), 15 Vdc on request
Current consumptionMeter: max. 100 mA; Controller: max. 250 mA
Operation pressure0.2 – 11 bar (3 – 160 psia) / GSC with valve type 4.5 and 8: max. 8 bara (120 psia)
Temperature (environment/gas)0 – 50°C (32 – 122°F)
Body MaterialsAnodized aluminum, optional stainless steel electropolished
SealsFKM, NBR, optional EPDM
Pressure sensitivity< 0.2% / bar of reading (typical N2)
Temperature sensitivity0.025% FS measuring range type per 1°C (<0.012% per 1°F)
Warm-up time< 1 sec. for full accuracy
INTEGRATION & INSTALLATION
Output signals analog0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, 2-10 V
Output signals digitalRS-485; Modbus RTU (Slave); LabView-VIs available / option: Profibus DP-V0, DP-V1
Process connectionG¼” (BSPP* female) up to 60 ln/min (64 SLPM)
G½” (BSPP* female) up to 450 ln/min (480 SLPM)*British Standard Pipe Parallel
Inlet sectionNone required
Electrical connectionSub D plug, 9 pole
Mounting orientationAny orientation (horizontal only above 5 bar)
SAFETY
Test pressure16 bara (240 psia)
Leak rate< 1 x 10-6 mbar l/s He
Environmental protectionIP50
EMCEN 61326-1

Any specific questions about this product?

Prefer a more personal approach? Call PhoneNumber or sent a mail to info@marktechnical.nl

We are Marktechnical

YOUR ADVANTAGES

  • Wide range of instruments, spare parts on stock
  • Fast delivery times 24/7
  • Field service
  • Experience team of professionals
  • Close cooperation with our customers
  • Well equiped workshop and test possibilities
  • Comprehensive list of brands
  • Personal and customized advice
  • ISO9001 certified

Product added