Technical Specifications red-y industrial series
MEASURING RANGES | |
Air/Full scale freely selectable | Body size ¼” from 0 … 25 mln/min to 0 … 60 ln/min (from 0 … 27 SCCM to 0 … 64 SLPM) Body size ½” from 0 … 60 ln/min to 0 … 450 ln/min(from 0 … 65 SLPM to 0 … 480 SLPM) |
INSTRUMENT VERSIONS | |
“Standard” The economic solution | Accuracy: ± 1.0% of full scale* Turndown ratio: 1 : 50 |
“Hi-Performance”With highest accuracy and turndown ratio(available for GIM < 200 ln/min (200 SLPM) /GIC < 150 ln/min (150 SLPM) (air)) | Accuracy: ± 0.3% of full scale + ± 0.5% of reading* Turndown ratio: 1 : 100*An additional error of ±0.25% may apply for analogue signals |
PERFORMANCE DATA | |
Media (real gas calibration) | Air, O2*, N2*, He, Ar, CO2, H2, CH4, C3H8 (other gases and gas mixtures on request) *O2 & N2 are calibrated with air |
Response time | Meter: 50 ms; Controller: 150 ms |
Repeatability | ± 0.2% of full scale |
Longterm stability | < 1% of measured value / year |
Power supply | 24 Vdc (18 – 30 Vdc), 15 Vdc on request |
Current consumption | Meter: max. 100 mA; Controller: max. 250 mA (except GIE) |
Operation pressure | 0.2 – 11 bara (3 – 160 psia) / GIC with valve type 4.5 and 8: max. 8 bara (120 psia) |
Temperature (environment/gas) | 0 – 50°C (32 – 122°F) |
Pressure sensitivity | <0.2% / bar (<0.014% / psi) of reading (typical N2) |
Temperature sensitivity | <0.025% FS measuring range type per 1°C (<0.012% per 1°F) |
Warm-up time | < 1 sec. for full accuracy |
MATERIALS | |
Body Materials | Stainless steel 316L (see operating instructions for wetted parts) |
Electronic Housing | Aluminum |
Seals | EPDM (FDA), optional FKM |
INTEGRATION & INSTALLATION | |
Output signals analog | 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, 2-10 V |
Output signals digital | RS-485; Modbus RTU (Slave); LabView-VIs available / option: Profibus DP-V0, DP-V1 |
Process connection | G¼” (BSPP* female) up to 60 ln/min (64 SLPM) G½” (BSPP* female) up to 450 ln/min (480 SLPM)*British Standard Pipe Parallel |
Inlet section | None required |
Electrical connection | Cable gland with compression fitting / Option: M12 plug (DIN-standard) (both connection IP67 protected) |
Mounting orientation | All orientations are possible. We recommend horizontal mounting. Please contact the manufacturer for further information. |
SAFETY | |
Test pressure | 16 bara (240 psia) |
Leak rate | < 1 x 10-6 mbar l/s He |
Environmental protection | IP67 (conforms to NEMA 6) |
EMC | EN 61326-1 |
ATEX Certification | II 3G nA IIC T4 Gc (Category 3 / Zone 2) II 3D Ex tc IIIC T100°C Dc (Category 3 / Zone 22) |
- software get red-y product information
- red-y smart series operating instructions digital communication
- red-y industrial series product information
- red-y industrial series options
- red-y industrial series operating instructions
- atex declaration of conformity
- labVIEW VIs (labview 2010 and higher).zip
- labVIEW VIs (abview 86 and higher).zip
- labVIEW VIs (labview 6 and higher).zip
- software get red-y v56.zip
Product variations
Product nr. | Setup | Size | Estimate |
---|---|---|---|
Red-Y-GIM-1/4 | Red-y industrial meter GIM | 1/4" | |
Red-Y-GIM-1/2 | Red-y industrial meter GIM | 1/2" | |
Red-Y-GIC-1/4 | Red-y industrial controller GIC | 1/4" | |
Red-Y-GIC-1/2 | Red-y industrial controller GIC | 1/2" | |
Red-Y-GIE-1/4 | Red-y Industrial controller GIE | 1/4" | |
Red-Y-GIE-1/2 | Red-y Industrial controller GIE | 1/2" |
Any specific questions about this product?
Prefer a more personal approach? Call PhoneNumber or sent a mail to info@marktechnical.nl